Merlin Gerin Multi — 9 Ic 2000 P Manual !!top!!
The front panel of the IC 2000 P features an intuitive interface consisting of a brightness adjustment dial and LED status indicators. 1. Setting the Lux Threshold
Features a built-in programmable time switch. The circuit only activates if both the light is low enough
Includes 42 memory settings for a 7-day (weekly) cycle with a minimum interval of 1 minute. Power Supply: Standard 230 V AC (+10% / -15%) at 50/60 Hz. Switching Capacity: Merlin Gerin Multi 9 Ic 2000 P Manual
: Photocell sensor connection (maximum distance of 100m). Terminals 2 & 4 : Output contact to the load or contactor. Programming Guide
Clip the IC 2000 P unit onto a standard 35mm DIN rail inside your electrical distribution board. Ensure adequate ventilation space around the module. Photoelectric Cell (Sensor) Placement Mount the external sensor outdoors. The front panel of the IC 2000 P
Remove the cover from the sensor. After roughly 60 to 80 seconds (the switch-off delay), the red LED will turn off, extinguishing the lights. Troubleshooting Guide Potential Cause Recommended Action No power supply to the module. Verify voltage across Terminals 1 and 2 using a multimeter. Lux threshold is set too low. Turn the potentiometer clockwise toward a higher Lux value. Sensor wired incorrectly or broken.
Choose the day, hour, and minute for the ON action, followed by the OFF action for 42 possible steps. The circuit only activates if both the light
The device's programming logic merges twilight and time functions.
Connect your lights to the output relay (terminals 3 and 5). ⚙️ Adjustment & Calibration The unit features two main dials on the front face: