Imagine you’ve just deployed a WinCC Runtime Advanced project to a new Industrial PC (IPC). The system boots, the HMI screens appear, but suddenly, an annoying popup declares the logging license is missing. Step 1: Check the Project Configuration The most common cause is that you’ve enabled Alarm Logs in TIA Portal. The Problem:
WinCC (Windows Control Center) is a supervisory control and data acquisition (SCADA) system developed by Siemens. It is widely used for monitoring, controlling, and data acquisition in various industries. To utilize WinCC's advanced features, including logging, a valid license key is required.
Encountering the error in Siemens WinCC Runtime Advanced can immediately halt your industrial automation project. This specific error typically triggers when a WinCC Runtime application attempts to execute data logging or alarm logging functions without the appropriate license installed on the host PC. Imagine you’ve just deployed a WinCC Runtime Advanced
: If a license is marked as defective, Alex had to contact Siemens Technical Support to have it restored. To prevent this in the future, Alex installed a UPS to ensure a clean shutdown.
Ensure the license is transferred to the correct drive (typically the C: drive) where the Runtime is active. The Problem: WinCC (Windows Control Center) is a
Navigate to . Look for any configured data logs storing process tag records into .csv , .txt , or database files. If you are trending variables historically over time on a Trend View object, an underlying Data Log must exist. 2. Alarm Logs
Verify the exact name of the license; it must be WinCC Logging for Runtime Advanced. : Encountering the error in Siemens WinCC Runtime Advanced
If these steps do not resolve the issue, please provide details about your specific WinCC version and the exact actions you performed so that further, more specialized assistance can be offered.
You have a 512-tag license. You configured data logging for 600 tags. The system will throw "License key not available for WinCC logging" because you exceed the allowed quantity.
In WinCC Runtime Advanced, licensing is granular compared to comfort panels. The base license (or higher) is sufficient to run the application, but it does not include the functionalities for archiving or logging. If your project utilizes: Tag Logging (Archives) Alarm Logging (Alarm Archives) Recipes
, a plant engineer who just finished setting up a process monitoring system on a PC using . Everything looked perfect until Alex hit the "Start Runtime" button and was greeted by a persistent pop-up: "License key not available! WinCC Logging for Runtime Advanced."